Yizhou Electric Vehicle Maintenance Company
The increase of power battery capacity of new energy vehicles: the fast charging performance of the power battery determines the ceiling of the fast charging pile. The development of DC fast charging pile requires the cooperation of the power battery. At present, battery manufacturers such as Ningde Times and BYD are trying to improve the energy density of batteries to enhance the endurance. In 2020, the energy density of new pure electric passenger vehicles has basically exceeded 150Wh/kg, and the average endurance mileage has exceeded 400km. The improvement of the endurance mileage of new energy vehicles has improved the practicability of high-power DC public piles, and accelerated the preference of vehicle owners for DC piles, which is the key reason why DC piles will become the choice direction of public piles in the future.
Yizhou Electric Vehicle Maintenance Company
According to the new national standard, the charging plug standard of different models in the future is the same. Xu Xinchao said, "Although there will be differences in voltage and power, theoretically it can be used in the same charging point. In addition, the new national standard attaches particular importance to the safety of the charging pile, which has always been the top priority. The standardized charging pile of new energy vehicles will automatically cut off power after charging, making breakthroughs in insulation and avoiding electric shock in rainy days, so as to avoid unnecessary dangers for new energy owners during charging. ".
Yizhou Electric Vehicle Maintenance Company
9. Anti rust (anti oxidation) protection The iron shell of the charging pile (bolt) and the exposed iron support and parts shall be provided with double-layer anti rust measures, and the non-ferrous metal shell shall also be provided with anti oxidation protective film or anti oxidation treatment; 10. The wind protection charger installed on the platform and exposed parts shall be able to withstand the relative wind speed in different areas and at different heights specified in Table 9 of GB/T 4797.5-9 Natural Environmental Conditions for Electrical and Electronic Products - Precipitation and Wind; 11. The shell door of the anti-theft protection electric pile (bolt) shall be equipped with an anti-theft lock, and the bolt fixing the AC charging pile (bolt) must be installed or removed after opening the shell door; 12. The temperature rise requires that the AC charging pile (plug) operates continuously under rated load for a long time, and the temperature rise of internal heating elements and parts shall not exceed the provisions in Table 2 of Q/GDW 397 2009;

Yizhou Electric Vehicle Maintenance Company
The control circuit of the electric vehicle charging pile (plug) is mainly completed by the embedded ARM processor. Users can swipe their cards to carry out user authentication, balance query, billing query and other functions, and can also provide voice output interface to achieve voice interaction. The user can select four charging modes according to the indication of the LCD screen: charging on time, charging according to the quantity of electricity, automatic charging, charging according to the mileage, etc. The electric vehicle charger controller and concentrator use CAN bus for data interaction, and the concentrator and server platform use wired Internet or wireless GPRS network for data interaction. For security reasons, the electricity billing and amount data are encrypted securely.
Yizhou Electric Vehicle Maintenance Company
What should be paid attention to when charging electric vehicle batteries? When the electric vehicle starts and goes uphill, it is necessary to avoid emergency braking and acceleration as much as possible, because large current discharge will be formed during this process, which will damage the performance of the battery. There are also two points that need special attention when stopping for a long time. 1. Parking without power supply should be avoided: unlike traditional gasoline vehicles, electric vehicles have their own "unique taste" for the state of vehicle parking. If the "hungry stomach" is used too long, it will "rebel". When the electric vehicle is parked in the case of power loss, the battery is prone to sulfation, blocking the electric ion channel, resulting in insufficient charging and declining battery capacity. 2. Deep discharge shall be carried out regularly: when the electric vehicle is almost out of power, undervoltage protection will automatically occur, but during this process, its voltage is unstable, and it will also be up and down, causing repeated undervoltage protection status

Yizhou Electric Vehicle Maintenance Company
AC type: Technical requirements for AC charging pile (plug) 1. Requirements for environmental conditions: ① Working environment temperature: - 20 ℃~+50 ℃; ② Relative humidity: 5%~95%; ③ Altitude: ≤ 1000m; ④ Installation site: outdoor; ⑤ Seismic capacity: ground horizontal acceleration 0.3g; Ground vertical acceleration 0.15g; The equipment shall be able to withstand three continuous sine waves under simultaneous action, and the safety factor shall be greater than 1.67; 2. Structural requirements: ① The shell of AC charging pile (bolt) shall be firm; ② In structure, it is necessary to prevent hands from easily touching the exposed part; ③ The AC charging post (bolt) shall be a steel composite structure with a thickness of more than 1.0, and the surface shall be treated with plastic immersion, and the requirements for heat dissipation shall be fully considered. The charging pile (bolt) shall have good shielding function against electromagnetic interference; ④ The charging pile (bolt) shall have sufficient support strength;